Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127.667
Filtrar
1.
J Mater Chem B ; 12(16): 3908-3916, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38567452

RESUMEN

The fabrication of shape-selective coinage metal nanoclusters (MNCs) has promising applications due to their exceptional physical and chemical molecule-like properties. However, the stability of the specific geometry of the nanoclusters, such as their cubic shapes, is unclear and has been unraveled by assessing the nanoclusters' interactions with different environments. In this work, we investigate the morphological stability of cubic structured, coinage metal nanoclusters of varying sizes ranging from 14 to 1099 atoms. The impact of solvent environments like water and the presence of ionic liquids (IL) on the stabilization of the MNCs were assessed using molecular dynamics (MD) simulations. In general, smaller MNCs composed of less than 256 atoms encountered structural distortion easily compared to the larger ones, which preserved their cubic morphology with minimal surface aberrations in water. However, in the presence of 4M 1-butyl-1,1,1-trimethyl ammonium methane sulfonate [N1114][C1SO3] IL solution, the overall cubic shape of the MNCs was successfully preserved. Strikingly, it is observed that in contrast to the noble MNCs like Au and Ag, the cubic morphology for Cu MNCs with sizes less than 256 atoms exhibited significant stability even in the absence of IL.


Asunto(s)
Cobre , Nanopartículas del Metal , Simulación de Dinámica Molecular , Cobre/química , Nanopartículas del Metal/química , Líquidos Iónicos/química , Tamaño de la Partícula , Propiedades de Superficie , Agua/química
2.
Luminescence ; 39(4): e4746, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38644460

RESUMEN

The use of photochromism to increase the credibility of consumer goods has shown great promise. To provide mechanically dependable anticounterfeiting nanofibres, it has also been critical to improve the engineering processes of authentication patterns. Mechanically robust and photoluminescent electrospun poly(ethylene oxide)/glass (PGLS) nanofibres (150-350 nm) immobilized with nanoparticles of lanthanide-doped aluminate (NLA; 8-15 nm) were developed using electrospinning technology for anticounterfeiting purposes. The provided nanofibrous membranes changed colour from transparent to green when irradiated with ultraviolet light. By delivering NLA with homogeneous distribution without aggregations, we were able to keep the nanofibrous membrane transparent. When excited at 365 nm, NLA@PGLS nanofibres showed an emission intensity at 517 nm. The hydrophobicity of NLA@PGLS nanofibres improved by raising the pigment concentration as the contact angle was increased from 146.4° to 160.3°. After being triggered by ultraviolet light, NLA@PGLS showed quick and reversible photochromism without fatigue. It was shown that the suggested method can be applied to reliably produce various anticounterfeiting materials.


Asunto(s)
Vidrio , Nanofibras , Polietilenglicoles , Rayos Ultravioleta , Nanofibras/química , Polietilenglicoles/química , Vidrio/química , Tamaño de la Partícula , Propiedades de Superficie
3.
Pediatr Dent ; 46(2): 135-141, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38664912

RESUMEN

Purpose: To compare surface roughness and bacterial colonization of Streptococcus mutans to 3D printed (3DP), milled (M), and conventional (CV) acrylic resin. Methods: Thirty-six discs (n equals 12 per group) were fabricated from 3DP, M, and CV materials. One surface of sample was polished (Po); the opposite surface was left unpolished (UPo). Surface roughness (µm) was assessed using a contact profilometer. The specimens were placed in S. mutans suspension and incubated at 37 degrees Celsius overnight. The attached colonies were separated using a sonicator, and the resulting solution was diluted to 10-3 to assess colony-forming units per milliliter (CFU/ml) after 48 hours. The colonies were categorized into a quantitative S. mutans (QS) index. Data were analyzed using one-way ANOVA, chi-squares, and multivariate analysis of variance analysis with the least significant difference (LSD) post-hoc test (P<0.05). Results: Roughness average (Ra) values of CV were higher than 3DP and M for UPo surfaces (P<0.001; 3DP=0.10; M=0.13; CV=0.26 µm, respectively). For Po and UPo surfaces, the CV harbored more S. mutans colonies than M and 3DP (P<0.001; 3DP=5.2x10 6 ; M=4.7x10 6 ; CV=1.49x10 7 CFU/ml, respectively). M group had the lowest range of QS scores, while CV had the highest range (P<0.001). Conclusions: Digitally manufactured material provides smoother surfaces than the conventional group, resulting in fewer Streptococcus mutans colonies. However, all the material groups must still be adequately polished to prevent the colonization of S. mutans, regardless of the manufacturing methods, as higher S. mutans counts were observed with an increase in surface roughness values.


Asunto(s)
Resinas Acrílicas , Impresión Tridimensional , Streptococcus mutans , Propiedades de Superficie , Streptococcus mutans/crecimiento & desarrollo , Técnicas In Vitro , Materiales Dentales , Ensayo de Materiales , Humanos , Recuento de Colonia Microbiana
4.
Soft Matter ; 20(16): 3425-3435, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38623617

RESUMEN

Understanding the interactions of pathogenic droplets with surfaces is crucial to biomedical applications. In this study, using E. coli as the model microbe, we investigate the impact of a bacteria-laden droplet on different substrates, both bare and antimicrobial. In doing so, we unveil the significance of kinetic energy and spreading parameters of the impacting droplet in determining the microbes' proliferation capabilities. Our results indicate an inverse relationship between the impact Weber number and the bacterial ability to proliferate. We reveal that the mechanical stress generated during impact impedes the capabilities of microbes present inside the droplet to create their progeny. Following an order analysis of the mechanical stress generated, we argue that the impact does not induce lysis-driven cell death of the bacteria; rather, it promotes a stress-driven transition of viable bacteria to a viable-but-non-culturable (VBNC) state. Furthermore, variations in the concentration of particles on the antimicrobial surfaces revealed the role of the post-impact spreading behaviour in dictating bacterial proliferation capabilities. Contrary to the conventional notion, we demonstrate that during the early stages of interaction, a bare substrate may outperform an antibacterial substrate in the inactivation of the bacterial load. Finally, we present an interaction map illustrating the complex relationship between bacterial colony-forming units, bactericide concentration on the surface, and the impact Weber number. We believe that the inferences of the study, highlighting the effect of mechanical stresses on the soft cell wall of microbes, could be a useful design consideration for the development of antimicrobial surfaces.


Asunto(s)
Escherichia coli , Propiedades de Superficie , Escherichia coli/fisiología , Escherichia coli/efectos de los fármacos , Estrés Mecánico , Antibacterianos/farmacología , Antibacterianos/química
5.
J Dent Res ; 103(5): 516-525, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38581213

RESUMEN

Titanium (Ti)-based biomaterials lack inherent antimicrobial activities, and the dental plaque formed on the implant surface is one of the main risk factors for implant infections. Construction of an antibacterial surface can effectively prevent implant infections and enhance implant success. Silver nanoparticles (AgNPs) exhibit broad antibacterial activity and a low tendency to induce drug resistance, but AgNPs easily self-aggregate in the aqueous environment, which significantly impairs their antibacterial activity. In this study, UiO-66/AgNP (U/A) nanocomposite was prepared, where zirconium metal-organic frameworks (UiO-66) were employed as the confinement matrix to control the particle size and prevent aggregation of AgNPs. The bactericidal activity of U/A against methicillin-resistant Staphylococcus aureus and Escherichia coli increased nearly 75.51 and 484.50 times compared with individually synthesized Ag. The antibacterial mechanism can be attributed to the enhanced membrane rupture caused by the ultrafine AgNPs on UiO-66, leading to protein leakage and generation of intracellular reactive oxygen species. Then, U/A was loaded onto Ti substrates (Ti-U/A) by using self-assembly deposition methods to construct an antibacterial surface coating. Ti-U/A exhibited excellent antibacterial activities and desired biocompatibility both in vitro and in vivo. The U/A nanocomposite coating technique is thus expected to be used as a promising surface modification strategy for Ti-based dental implants for preventing dental implant infections.


Asunto(s)
Antibacterianos , Materiales Biocompatibles Revestidos , Implantes Dentales , Escherichia coli , Nanopartículas del Metal , Staphylococcus aureus Resistente a Meticilina , Plata , Circonio , Plata/farmacología , Implantes Dentales/microbiología , Antibacterianos/farmacología , Nanopartículas del Metal/uso terapéutico , Escherichia coli/efectos de los fármacos , Circonio/química , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Materiales Biocompatibles Revestidos/farmacología , Estructuras Metalorgánicas/farmacología , Estructuras Metalorgánicas/química , Animales , Titanio/química , Nanocompuestos/química , Propiedades de Superficie , Ratones , Especies Reactivas de Oxígeno
6.
Shanghai Kou Qiang Yi Xue ; 33(1): 36-39, 2024 Feb.
Artículo en Chino | MEDLINE | ID: mdl-38583022

RESUMEN

PURPOSE: To study the effect of different cleaning methods on the shear bond strength of self-adhesive resin cement to saliva-contaminated high translucency zirconia and surface wettability. METHODS: Eighty zirconia specimens were randomly divided into 5 groups (n=16), i.e., control group(not contaminated), 75% ethanol group,cleaning paste group,airborne-particle abrasion group, and atmospheric pressure cold plasma group. The contact angles was measured, shear bond strength were examined, and fracture types were determined. SPSS 26.0 software package was used for statistical analysis of the data. RESULTS: The atmospheric pressure cold plasma group produced the lowest contact angle(P<0.05). The shear bond strength of the airborne-particle abrasion group, the cleaning paste group and the atmospheric pressure cold plasma group respectively were similar to the control group without significant difference(P>0.05), while those were significantly higher than 75% ethanol group(P<0.05). The mixed fracture mode of the atmospheric pressure cold plasma group evidently increased. CONCLUSIONS: Airborne-particle abrasion, cleaning paste and atmospheric pressure cold plasma overcome the effects of saliva contamination, producing the shear bond strength to zirconia similar to the control group. The atmospheric pressure cold plasma improves hydrophilicity of high translucency zirconia significantly.


Asunto(s)
Recubrimiento Dental Adhesivo , Gases em Plasma , Humectabilidad , Propiedades de Superficie , Cementos de Resina , Circonio/química , Etanol , Ensayo de Materiales , Resistencia al Corte , Análisis del Estrés Dental
7.
J Dent Res ; 103(5): 467-476, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38616679

RESUMEN

Implant osseointegration is reduced in patients with systemic conditions that compromise bone quality, such as osteoporosis, disuse syndrome, and type 2 diabetes. Studies using rodent models designed to mimic these compromised conditions demonstrated reduced bone-to-implant contact (BIC) or a decline in bone mineral density. These adverse effects are a consequence of disrupted intercellular communication. A variety of approaches have been developed to compensate for the altered microenvironment inherent in compromised conditions, including the use of biologics and implant surface modification. Chemical and physical modification of surface properties at the microscale, mesoscale, and nanoscale levels to closely resemble the surface topography of osteoclast resorption pits found in bone has proven to be a highly effective strategy for improving implant osseointegration. The addition of hydrophilicity to the surface further enhances osteoblast response at the bone-implant interface. These surface modifications, applied either alone or in combination, improve osseointegration by increasing proliferation and osteoblastic differentiation of osteoprogenitor cells and enhancing angiogenesis while modulating osteoclast activity to achieve net new bone formation, although the specific effects vary with surface treatment. In addition to direct effects on surface-attached cells, the communication between bone marrow stromal cells and immunomodulatory cells is sensitive to these surface properties. This article reports on the advances in titanium surface modifications, alone and in combination with novel therapeutics in animal models of human disease affecting bone quality. It offers clinically translatable perspectives for clinicians to consider when using different surface modification strategies to improve long-term implant performance in compromised patients. This review supports the use of surface modifications, bioactive coatings, and localized therapeutics as pragmatic approaches to improve BIC and enhance osteogenic activity from both structural and molecular standpoints.


Asunto(s)
Interfase Hueso-Implante , Implantes Dentales , Modelos Animales de Enfermedad , Oseointegración , Propiedades de Superficie , Oseointegración/fisiología , Animales , Osteoblastos/fisiología , Humanos , Osteogénesis/fisiología , Osteoclastos , Implantación Dental Endoósea
8.
Biomed Mater ; 19(3)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38626780

RESUMEN

Wool derived keratin, due to its demonstrated ability to promote bone formation, has been suggested as a potential bioactive material for implant surfaces. The aim of this study was to assess the effects of keratin-coated titanium on osteoblast functionin vitroand bone healingin vivo. Keratin-coated titanium surfaces were fabricated via solvent casting and molecular grafting. The effect of these surfaces on the attachment, osteogenic gene, and osteogenic protein expression of MG-63 osteoblast-like cells were quantifiedin vitro. The effect of these keratin-modified surfaces on bone healing over three weeks using an intraosseous calvaria defect was assessed in rodents. Keratin coating did not affect MG-63 proliferation or viability, but enhanced osteopontin, osteocalcin and bone morphogenetic expressionin vitro. Histological analysis of recovered calvaria specimens showed osseous defects covered with keratin-coated titanium had a higher percentage of new bone area two weeks after implantation compared to that in defects covered with titanium alone. The keratin-coated surfaces were biocompatible and stimulated osteogenic expression in adherent MG-63 osteoblasts. Furthermore, a pilot preclinical study in rodents suggested keratin may stimulate earlier intraosseous calvaria bone healing.


Asunto(s)
Regeneración Ósea , Proliferación Celular , Materiales Biocompatibles Revestidos , Queratinas , Osteoblastos , Osteogénesis , Cráneo , Titanio , Titanio/química , Osteoblastos/efectos de los fármacos , Osteoblastos/citología , Osteoblastos/metabolismo , Regeneración Ósea/efectos de los fármacos , Animales , Queratinas/química , Queratinas/metabolismo , Humanos , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Proliferación Celular/efectos de los fármacos , Cráneo/efectos de los fármacos , Cráneo/lesiones , Osteogénesis/efectos de los fármacos , Ratas , Propiedades de Superficie , Masculino , Línea Celular , Adhesión Celular/efectos de los fármacos , Ensayo de Materiales , Supervivencia Celular/efectos de los fármacos , Ratas Sprague-Dawley
9.
Int J Oral Maxillofac Implants ; 39(2): 235-242, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38657216

RESUMEN

PURPOSE: To analyze the effectiveness of coating of abutments with antimicrobial agents and their influence on the physicochemical and biologic properties of the coated materials. MATERIALS AND METHODS: This work was registered in Open Science Framework (osf.io/6tkcp) and followed the PRISMA protocols. A search of two independent reviewers of articles published up to October 29, 2021, was performed in the Embase, PubMed, Science Direct, and Scopus databases. RESULTS: The databases found a total of 1,474 references. After excluding the duplicates, 1,050 remained. After reading the titles and abstracts and applying the inclusion criteria, 13 articles remained and were read in full. A total of 8 articles were included in this systematic review. Different antimicrobial agents have been used to coat abutments, including graphene oxide, polydopamine, titanium and zirconium nitride, lactoferrin, tetracycline, silver, and doxycycline with varied release times. Titanium-coated silver showed a better antimicrobial agent release time of up to 28 days. Chemical analysis confirmed the presence of antimicrobials on the surface after coating. Different pathogenic microorganisms, such as Streptococcus sanguinis, Streptococcus oralis, and Staphylococcus aureus, were inhibited when in contact with the coated surface. CONCLUSIONS: This review showed that there is still no consensus on which is the better antimicrobial agent and which coated materials have the better performance. However, the association of surface coating of abutments with antimicrobials is feasible and can benefit many patients, which can support their clinical use to favor the healing process and prevent infections that can lead to treatment failure with dental implants.


Asunto(s)
Antiinfecciosos , Pilares Dentales , Humanos , Antiinfecciosos/farmacología , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Pilares Dentales/microbiología , Propiedades de Superficie , Titanio/química
10.
Clin Oral Investig ; 28(5): 271, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38658431

RESUMEN

OBJECTIVES: This in vitro study evaluated the effect of different colouring solutions and primer systems used in the bonding of brackets on enamel colour change and bond strength. MATERIALS AND METHODS: 120 premolar teeth were divided into four main groups; brackets were bonded with 37% orthophosphoric acid + Transbond XT Primer in Group 1, 3 M Single Bond Universal in Group 2, Transbond Plus SEP in Group 3, and G-Premio Bond in Group 4. Each group was divided into three subgroups, and the teeth were placed in a cup containing coffee and tea mixture, in a cup containing cola and in distilled water. A bond strength test was applied to all teeth. Colour measurements of all teeth were performed at 2 different times: before bonding and after the bond strength test. RESULTS: The average bond strength of the 37% orthophosphoric acid group was higher than that of the other groups. The effect of primer and solution groups on colour change was statistically significant (p = 0.001 and p = 0.023, respectively). CONCLUSIONS: In this study, the bond strength was clinically sufficient in all primer groups. The highest colour change was observed when the tea-coffee solution and Transbond Plus SEP primer were used. CLINICAL RELEVANCE: This study has identified enamel discoloration and bond strength from different colouring solutions and primer systems used for bonding braces, which can be used to inform clinicians and patients to achieve better treatment results.


Asunto(s)
Diente Premolar , Bisfenol A Glicidil Metacrilato , Recubrimiento Dental Adhesivo , Soportes Ortodóncicos , Cementos de Resina , Resistencia al Corte , Humanos , Recubrimiento Dental Adhesivo/métodos , Técnicas In Vitro , Cementos de Resina/química , Color , Colorantes , Ensayo de Materiales , Esmalte Dental/química , Análisis del Estrés Dental , Ácidos Fosfóricos/química , Propiedades de Superficie , Té/química , Grabado Ácido Dental
11.
Biosensors (Basel) ; 14(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38667159

RESUMEN

The screen-printed carbon electrode (SPCE) is a useful technology that has been widely used in the practical application of biosensors oriented to point-of-care testing (POCT) due to its characteristics of cost-effectiveness, disposability, miniaturization, wide potential window, and simple electrode design. Compared with gold or platinum electrodes, surface modification is difficult because the carbon surface is chemically or physically stable. Oxygen plasma (O2) can easily produce carboxyl groups on the carbon surface, which act as scaffolds for covalent bonds. However, the effect of O2-plasma treatment on electrode performance remains to be investigated from an electrochemical perspective, and sensor performance can be improved by clarifying the surface conditions of plasma-treated biosensors. In this research, we compared antibody modification by plasma treatment and physical adsorption, using our novel immunosensor based on gold nanoparticles (AuNPs). Consequently, the O2-plasma treatment produced carboxyl groups on the electrode surface that changed the electrochemical properties owing to electrostatic interactions. In this study, we compared the following four cases of SPCE modification: O2-plasma-treated electrode/covalent-bonded antibody (a); O2-plasma-treated electrode/physical adsorbed antibody (b); bare electrode/covalent-bonded antibody (c); and bare electrode/physical absorbed antibody (d). The limits of detection (LOD) were 0.50 ng/mL (a), 9.7 ng/mL (b), 0.54 ng/mL (c), and 1.2 ng/mL (d). The slopes of the linear response range were 0.039, 0.029, 0.014, and 0.022. The LOD of (a) was 2.4 times higher than the conventional condition (d), The slope of (a) showed higher sensitivity than other cases (b~d). This is because the plasma treatment generated many carboxyl groups and increased the number of antibody adsorption sites. In summary, the O2-plasma treatment was found to modify the electrode surface conditions and improve the amount of antibody modifications. In the future, O2-plasma treatment could be used as a simple method for modifying various molecular recognition elements on printed carbon electrodes.


Asunto(s)
Técnicas Biosensibles , Carbono , Electrodos , Oro , Oxígeno , Carbono/química , Oro/química , Nanopartículas del Metal/química , Propiedades de Superficie , Límite de Detección , Técnicas Electroquímicas , Adsorción
12.
Biosensors (Basel) ; 14(4)2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38667192

RESUMEN

Rapid surface charge mapping of a solid surface remains a challenge. In this study, we present a novel microchip based on liquid crystals for assessing the surface charge distribution of a planar or soft surface. This chip enables rapid measurements of the local surface charge distribution of a charged surface. The chip consists of a micropillar array fabricated on a transparent indium tin oxide substrate, while the liquid crystal is used to fill in the gaps between the micropillar structures. When an object is placed on top of the chip, the local surface charge (or zeta potential) influences the orientation of the liquid crystal molecules, resulting in changes in the magnitude of transmitted light. By measuring the intensity of the transmitted light, the distribution of the surface charge can be accurately quantified. We calibrated the chip in a three-electrode configuration and demonstrated the validity of the chip for rapid surface charge mapping using a borosilicate glass slide. This chip offers noninvasive, rapid mapping of surface charges on charged surfaces, with no need for physical or chemical modifications, and has broad potential applications in biomedical research and advanced material design.


Asunto(s)
Cristales Líquidos , Propiedades de Superficie , Cristales Líquidos/química , Compuestos de Estaño/química , Electrodos , Técnicas Biosensibles
13.
Cells ; 13(8)2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38667271

RESUMEN

Even with the best infection control protocols in place, the risk of a hospital-acquired infection of the surface of an implanted device remains significant. A bacterial biofilm can form and has the potential to escape the host immune system and develop resistance to conventional antibiotics, ultimately causing the implant to fail, seriously impacting patient well-being. Here, we demonstrate a 4 log reduction in the infection rate by the common pathogen S. aureus of 3D-printed polyaryl ether ketone (PAEK) polymeric surfaces by covalently binding the antimicrobial peptide Mel4 to the surface using plasma immersion ion implantation (PIII) treatment. The surfaces with added texture created by 3D-printed processes such as fused deposition-modelled polyether ether ketone (PEEK) and selective laser-sintered polyether ketone (PEK) can be equally well protected as conventionally manufactured materials. Unbound Mel4 in solution at relevant concentrations is non-cytotoxic to osteoblastic cell line Saos-2. Mel4 in combination with PIII aids Saos-2 cells to attach to the surface, increasing the adhesion by 88% compared to untreated materials without Mel4. A reduction in mineralisation on the Mel4-containing surfaces relative to surfaces without peptide was found, attributed to the acellular portion of mineral deposition.


Asunto(s)
Péptidos Antimicrobianos , Benzofenonas , Polímeros , Impresión Tridimensional , Prótesis e Implantes , Staphylococcus aureus , Humanos , Staphylococcus aureus/efectos de los fármacos , Péptidos Antimicrobianos/farmacología , Péptidos Antimicrobianos/química , Péptidos Antimicrobianos/metabolismo , Prótesis e Implantes/efectos adversos , Polímeros/química , Polímeros/farmacología , Biopelículas/efectos de los fármacos , Cetonas/química , Cetonas/farmacología , Osteoblastos/efectos de los fármacos , Osteoblastos/metabolismo , Polietilenglicoles/química , Polietilenglicoles/farmacología , Propiedades de Superficie , Huesos/efectos de los fármacos , Huesos/metabolismo , Ortopedia
14.
ACS Sens ; 9(4): 1978-1991, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38564767

RESUMEN

This paper presents a sponge-based electrochemical sensor for rapid, on-site collection and analysis of infectious viruses on solid surfaces. The device utilizes a conducting porous sponge modified with graphene, graphene oxide, and specific antibodies. The sponge serves as a hydrophilic porous electrode capable of liquid collection and electrochemical measurements. The device operation involves spraying an aqueous solution on a target surface, swiping the misted surface using the sponge, discharging an electrolyte solution with a simple finger press, and performing in situ incubation and electrochemical measurements. By leveraging the water-absorbing ability of the biofunctionalized conducting sponge, the sensor can effectively collect and quantify virus particles from the surface. The portability of the device is enhanced by introducing a push-release feature that dispenses the liquid electrolyte from a miniature reservoir onto the sensor surface. This reservoir has sharp edges to rupture a liquid sealing film with a finger press. The ability of the device to sample and quantify viral particles is demonstrated by using influenza A virus as the model. The sensor provided a calculated limit of detection of 0.4 TCID50/mL for H1N1 virus, along with a practical concentration range from 1-106 TCID50/mL. Additionally, it achieves a 15% collection efficiency from single-run swiping on a tabletop surface. This versatile device allows for convenient on-site virus detection within minutes, eliminating the need for sample pretreatment and simplifying the entire sample collecting and measuring process. This device presents significant potential for rapid virus detection on solid surfaces.


Asunto(s)
Técnicas Electroquímicas , Grafito , Subtipo H1N1 del Virus de la Influenza A , Virión , Grafito/química , Virión/química , Virión/aislamiento & purificación , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Subtipo H1N1 del Virus de la Influenza A/aislamiento & purificación , Propiedades de Superficie , Porosidad , Electrodos , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Límite de Detección , Humanos
15.
ACS Appl Mater Interfaces ; 16(15): 18503-18521, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38570902

RESUMEN

Biomaterials can induce an inflammatory response in surrounding tissues after implantation, generating and releasing reactive oxygen species (ROS), such as hydrogen peroxide (H2O2). The excessive accumulation of ROS may create a microenvironment with high levels of oxidative stress (OS), which subsequently accelerates the degradation of the passive film on the surface of titanium (Ti) alloys and affects their biological activity. The immunomodulatory role of macrophages in biomaterial osteogenesis under OS is unknown. This study aimed to explore the corrosion behavior and bone formation of Ti implants under an OS microenvironment. In this study, the corrosion resistance and osteoinduction capabilities in normal and OS conditions of the Ti-24Nb-4Zr-8Sn (wt %, Ti2448) were assessed. Electrochemical impedance spectroscopy analysis indicated that the Ti2448 alloy exhibited superior corrosion resistance on exposure to excessive ROS compared to the Ti-6Al-4V (TC4) alloy. This can be attributed to the formation of the TiO2 and Nb2O5 passive films, which mitigated the adverse effects of OS. In vitro MC3T3-E1 cell experiments revealed that the Ti2448 alloy exhibited good biocompatibility in the OS microenvironment, whereas the osteogenic differentiation level was comparable to that of the TC4 alloy. The Ti2448 alloy significantly alleviates intercellular ROS levels, inducing a higher proportion of M2 phenotypes (52.7%) under OS. Ti2448 alloy significantly promoted the expression of the anti-inflammatory cytokine, interleukin 10 (IL-10), and osteoblast-related cytokines, bone morphogenetic protein 2 (BMP-2), which relatively increased by 26.9 and 31.4%, respectively, compared to TC4 alloy. The Ti2448 alloy provides a favorable osteoimmune environment and significantly promotes the proliferation and differentiation of osteoblasts in vitro compared to the TC4 alloy. Ultimately, the Ti2448 alloy demonstrated excellent corrosion resistance and immunomodulatory properties in an OS microenvironment, providing valuable insights into potential clinical applications as implants to repair bone tissue defects.


Asunto(s)
Osteogénesis , Titanio , Corrosión , Especies Reactivas de Oxígeno , Peróxido de Hidrógeno , Materiales Biocompatibles , Aleaciones/química , Estrés Oxidativo , Propiedades de Superficie , Ensayo de Materiales
16.
J Mech Behav Biomed Mater ; 154: 106536, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38579394

RESUMEN

OBJECTIVE: This study aimed to conduct a comparison of trueness and physical and surface properties among five distinct types of additive manufactured (AM) zirconia crowns and zirconia crowns produced using the subtractive manufacturing (SM). MATERIAL AND METHODS: Zirconia crowns were fabricated using five distinct techniques, each varying in the method of slurry transfer and photocuring source. Each experimental group utilized either one of the four digital light processing (DLP)-based techniques (DLP spreading, DLP spreading gradation, DLP vat and DLP circular spreading) or the stereolithography (SLA)-based technique (SLA spreading). The control (CON) group employed SM. To assess accuracy, trueness was measured between the scan and reference data. To analyze the physical properties, voids were examined using high-energy spiral micro-computed tomography scans, and the crystal structure analysis was performed using X-ray diffraction (XRD). Surface roughness was assessed through laser scanning microscopy. RESULTS: Differences in the trueness of internal surfaces of crowns were found among the groups (P < 0.05). Trueness varied across the measurement surfaces (occlusal, lateral, and marginal) in all the groups except for the DLP spreading gradation group (P < 0.05). Voids were observed in all AM groups. All groups showed similar XRD patterns. All AM groups showed significantly greater surface roughness compared to the CON group (P < 0.001). CONCLUSION: The AM zirconia crowns showed bubbles and a rougher surface compared to the SM crowns. All groups exhibited typical zirconia traits and trueness levels within clinically acceptable limits, suggesting that current zirconia AM techniques could be suitable for dental applications.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Microtomografía por Rayos X , Circonio , Propiedades de Superficie
17.
J Mech Behav Biomed Mater ; 154: 106533, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38598918

RESUMEN

The present work aims to develop a production method of pre-sintered zirconia-toughened-alumina (ZTA) composite blocks for machining in a computer-aided design and computer-aided manufacturing (CAD-CAM) system. The ZTA composite comprised of 80% Al2O3 and 20% ZrO2 was synthesized, uniaxially and isostatically pressed to generate machinable CAD-CAM blocks. Fourteen green-body blocks were prepared and pre-sintered at 1000 °C. After cooling and holder gluing, a stereolithography (STL) file was designed and uploaded to manufacture disk-shaped specimens projected to comply with ISO 6872:2015. Seventy specimens were produced through machining of the blocks, samples were sintered at 1600 °C and two-sided polished. Half of the samples were subjected to accelerated autoclave hydrothermal aging (20h at 134 °C and 2.2 bar). Immediate and aged samples were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Optical and mechanical properties were assessed by reflectance tests and by biaxial flexural strength test, Vickers indentation and fracture toughness, respectively. Samples produced by machining presented high density and smooth surfaces at SEM evaluation with few microstructural defects. XRD evaluation depicted characteristic peaks of alpha alumina and tetragonal zirconia and autoclave aging had no effect on the crystalline spectra of the composite. Optical and mechanical evaluations demonstrated a high masking ability for the composite and a characteristic strength of 464 MPa and Weibull modulus of 17, with no significant alterations after aging. The milled composite exhibited a hardness of 17.61 GPa and fracture toughness of 5.63 MPa m1/2, which remained unaltered after aging. The synthesis of ZTA blocks for CAD-CAM was successful and allowed for the milling of disk-shaped specimens using the grinding method of the CAD-CAM system. ZTA composite properties were unaffected by hydrothermal autoclave aging and present a promising alternative for the manufacture of infrastructures of fixed dental prostheses.


Asunto(s)
Óxido de Aluminio , Cerámica , Ensayo de Materiales , Óxido de Aluminio/química , Cerámica/química , Propiedades de Superficie , Circonio/química , Diseño Asistido por Computadora , Materiales Dentales
18.
BMC Oral Health ; 24(1): 471, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38637799

RESUMEN

OBJECT: This study aimed to investigate the changes in the translucency and color of four different multi-layered zirconia materials when the sintering temperature were inaccurate. MATERIALS AND METHODS: Two hundred zirconia samples (11 × 11 × 1.0 mm) of four multi-layered zirconia, Upcera TT-GT (UG), Upcera TT-ML (UM), Cercon xt ML (CX), and Lava Esthetic (LE), were divided into five subgroups according to the sintering temperature: L1 (5% lower temperature), L2 (2.5% lower temperature), R (recommended sintering temperature), H2 (2.5% higher temperature), H1 (5% higher temperature). After sintering, color coordinates were measured. Then the translucency parameter (TP) values, and the color differences (between the inaccurate sintering temperature and the recommended temperature) of each zirconia specimen were calculated. Statistical analysis was performed by using three-way ANOVA tests, the one-way ANOVA, and Tukey's post hoc test. RESULTS: Three-way ANOVA results showed that material type, sintering temperature, specimen section, and their interactions significantly influenced the TP values (except for the interactions of specimen section and sintering temperature) (P < .05). TP values of zirconia specimens were significantly different in the inaccurate sintering temperatures (P < .05), except for the cervical and body sections of UG group (P > .05). Compared with recommended sintering temperature, higher sintering temperature caused higher TP values for CX, but lower for LE. Three-way ANOVA results showed that material type, sintering temperature, and their interactions significantly influenced the ∆E00 values (P < .05). There were no significant differences in ∆E00 values of UM and CX groups at different inaccurate sintering temperatures, and were clinical imperception (except for UM-L1) (∆E00 < 1.25). ∆E00 values of all zirconia specimens showed clinically acceptable (∆E00 < 2.23). CONCLUSION: The deviations in sintering temperature significantly influenced the translucency and color of tested multi-layered zirconia. The trends of translucency in the multi-layered zirconia depended on material type and the color changes of all zirconia materials were clinically acceptable at inaccurate sintering temperatures.


Asunto(s)
Cerámica , Circonio , Humanos , Temperatura , Ensayo de Materiales , Propiedades de Superficie , Color
19.
Database (Oxford) ; 20242024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557634

RESUMEN

The rapid growth in the number of experimental and predicted protein structures and more complicated protein structures poses a significant challenge for computational biology in leveraging structural information and accurate representation of protein surface properties. Recently, AlphaFold2 released the comprehensive proteomes of various species, and protein surface property representation plays a crucial role in protein-molecule interaction predictions, including those involving proteins, nucleic acids and compounds. Here, we proposed the first extensive database, namely ProNet DB, that integrates multiple protein surface representations and RNA-binding landscape for 326 175 protein structures. This collection encompasses the 16 model organism proteomes from the AlphaFold Protein Structure Database and experimentally validated structures from the Protein Data Bank. For each protein, ProNet DB provides access to the original protein structures along with the detailed surface property representations encompassing hydrophobicity, charge distribution and hydrogen bonding potential as well as interactive features such as the interacting face and RNA-binding sites and preferences. To facilitate an intuitive interpretation of these properties and the RNA-binding landscape, ProNet DB incorporates visualization tools like Mol* and an Online 3D Viewer, allowing for the direct observation and analysis of these representations on protein surfaces. The availability of pre-computed features enables instantaneous access for users, significantly advancing computational biology research in areas such as molecular mechanism elucidation, geometry-based drug discovery and the development of novel therapeutic approaches. Database URL:  https://proj.cse.cuhk.edu.hk/aihlab/pronet/.


Asunto(s)
Proteoma , ARN , Sitios de Unión , Bases de Datos de Proteínas , ARN/química , Proteínas de la Membrana , Propiedades de Superficie
20.
Sci Rep ; 14(1): 7624, 2024 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-38561345

RESUMEN

It is known that titanium (Ti) implant surfaces exhibit poor antibacterial properties and osteogenesis. In this study, chitosan particles loaded with aspirin, amoxicillin or aspirin + amoxicillin were synthesized and coated onto implant surfaces. In addition to analysing the surface characteristics of the modified Ti surfaces, the effects of the modified Ti surfaces on the adhesion and viability of rat bone marrow-derived stem cells (rBMSCs) were evaluated. The metabolic activities of Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) biofilms on the modified Ti surfaces were also measured in vitro. Moreover, S. aureus was tested for its antibacterial effect by coating it in vivo. Using water as the droplet medium, the contact angles of the modified Ti surfaces increased from 44.12 ± 1.75° to 58.37 ± 4.15°. In comparison to those of the other groups tested, significant increases in rBMSC adhesion and proliferation were observed in the presence of aspirin + amoxicillin-loaded microspheres, whereas a significant reduction in the metabolic level of biofilms was observed in the presence of aspirin + amoxicillin-loaded microspheres both in vitro and in vivo. Aspirin and amoxicillin could be used in combination to coat implant surfaces to mitigate bacterial activities and promote osteogenesis.


Asunto(s)
Amoxicilina , Quitosano , Indoles , Polímeros , Ratas , Animales , Amoxicilina/farmacología , Aspirina/farmacología , Titanio/farmacología , Quitosano/farmacología , Osteogénesis , Staphylococcus aureus , Escherichia coli , Antibacterianos/farmacología , Propiedades de Superficie , Materiales Biocompatibles Revestidos/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...